UNI-D Type SUS-10 2S040-10 3/8'' Stainless Steel Water Solenoid Valve

UNI-D Type SUS-10 2S040-10 3/8'' Stainless Steel Water Solenoid Valve

  • UNI-D Type SUS-10 2S040-10 3/8'' Stainless Steel Water Solenoid Valve
UNI-D Type SUS-10 2S040-10 3/8'' Stainless Steel Water Solenoid Valve
Détails sur le produit:
Lieu d'origine: LA CHINE
Nom de marque: Brando
Certification: CE
Numéro de modèle: 2S040-10
Conditions de paiement et expédition:
Quantité de commande min: 1 PC
Détails d'emballage: boîtes intérieures, cartons, palettes
Délai de livraison: 7 jours ouvrables
Conditions de paiement: L/C, T/T, Western Union
Capacité d'approvisionnement: 100000 PCs par mois
Contact
Description de produit détaillée
SÉRIE DE VALVE: série 2S Ref. Number: Type SUS-10 d'UNI-D
Tension: AC110V AV220V DC24V Action: À action directe
Taille de port: 3/8" pouce Médias: Gaz eau-air
Viscossity liquide: Au-dessous du 20H CST Puissance: Solénoïde
Matériel de corps: Acier inoxydable Matériel de diaphragme: NBR, FKM et EPDM
Surligner:

Vanne électromagnétique de l'eau SUS-10

,

vanne électromagnétique de l'eau 2S040-10

,

SUS-10 à action directe

UNI-D Type SUS-10 2S040-10 3/8'' Stainless Steel Water Solenoid Valve

 

2S Series Solenoid Valve: 2S025-06, 2S025-08, 2S040-10, 2S160-15, 2S200-20, 2S250-25, 2S350-35, 2S400-40, 2S500-50

2W Series Solenoid Valve: 2W025-06, 2W025-08, 2W040-10, 2W160-15, 2W200-20, 2W250-25, 2W350-35, 2W400-40, 2W500-50

Port Size Range: 1/4'', 3/8'', 1/2'', 3/4'', 1'', 1 1/4'', 1 1/2'', 2''

Voltages: 12VDC, 24VDC, 110VAC, 220VAC

 

The electric solenoid valve is made of high quality 304 stainless steel material, with long serving life. This electric solenoid valve is Normally Closed(N/C) Type, suitable for water, air, oil, gas transfer. It is suitable for automatic cleaning of electrical equipment, solar water heater, garden spray irrigation, infrared sensor cleaning device and so on.

 

Technical Data of 2W & 2S Solenoid Valve:

 

2W Series
2W025-08
2W040-10
2W160-15
2W200-20
2W250-25
2W350-35
2W400-40
2W500-50
2S Series
2S025-08
2S040-10
2S160-15
2S200-20
2S250-25
2S350-35
2S400-40
2S500-50
Orifice Size
2.5
4
15
20
25
35
40
50
Port Size
1/4''
3/8''
1/2''
3/4''
1''
1-1/4''
1-1/2''
2''
Medium
Water, Air, Gas, Oil
Action
Direct Acting
Semi-Direct Diaphragm Operated
Function
2 Way, Normally Closed
Fluid Viscosity
20 CST below
Pressure
Range
0 to 1.0 Mpa
Temp. Range
-5 to +85℃
 

 

Main dimension of 2W & 2S Series Solenoid Valves:
UNI-D Type SUS-10 2S040-10 3/8'' Stainless Steel Water Solenoid Valve 0

2S Series
2W Series
A
B
C
D
E
2S025-06
2W025-06
64.5
30
75
43
1/8''
2S025-08
2W025-08
64.5
30
75
43
1/4''
2S040-10
2W040-10
70.6
32
82.4
53
3/8''
2S160-10
2W160-10
101.5
57
117
69
3/8''
2S160-15
2W160-15
101.5
57
117
69
1/2''
2S200-20
2W200-20
107
57
123.5
73
3/4''
2S250-25
2W250-25
111.5
73.5
134.5
99
1''
2S350-35
2W350-35
142
95
172
123
1-1/4''
2S400-40
2W400-40
142
95
172
123
1-1/2''
2S500-50
2W500-50
172
123
209
168
2''

 

 

How to choose normally open or closed solenoid valve?
In general, we select solenoid valve type according to the continuous working period. Common types include normally open, normally closed and self-retaining type. Specific rules as blows:

When the solenoid valve has prolonged on state, and the opening time is much longer than the closing time, we choose normally open solenoid valve.
When the solenoid valve has long-term off state, and the closing time is much longer than the opening time, we should choose normally closed solenoid valve.
When the solenoid valve requires same time on the opening and closing, we should choose self-retaining type solenoid valve, also called double acting type.
For some working conditions used for safety protection, such as the furnace flame detecting and other conditions, normally open solenoid valve is not applicable; we should choose long-term electricity type.
For gas leak alarm device system, we should choose normally open type gas emergency shut-off solenoid valve. After closing, the solenoid valve should be started up manually.

 

Focus on your demands, Offer you best solution:

 

√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing

 